Hipot Tester
耐高溫測試儀
Model : TOS5101
The Kikusui TOS5101
* Specification
Output block
Applied Voltage 0 to 5/ 0 to 10 kV AC and DC
AC
Maximum Rated 500VA / 10 kV, 50 mA
Waveform Commercial line waveform
Voltage Regulation Max. 15% (for max. rated load to no load)
Switching Use of a zero turn-on switch
DC
Applied Voltage 50W / 10 kV, 5 mA
Ripple 100 Vp-p typ. at 10 kV, no load
200 Vp-p typ. at max. rated output
Maximum Rated Max. 3% (for max. rated load to no load)
Output Voltmeters
Analog Scale 10 kV full scale , AC/DC
Class JIS Class 2.5
Accuracy ±5% of full scale
AC Indication Mean value response / rms value scale
Digital Full Scale 5 kV/ 10 kV full scale
Accuracy ±1.5% of full scale
AC Response Mean value response / rms value display
Ammeter
Digital Accuracy ±(5% + 20μA) of upper cutoff current
AC Response Mean value response / rms value displayType of Judgement
Pass/fail Judgement Function
- FAIL judgement
*When current detected above upper cutoff current
*When current detected below lower cutoff current
(FAIL signal generated when FAIL judgement made)
- PASS judgement
*When set time has elapsed and no abnormality is
detected
Upper cutoff current setting range AC: 0.1 to 55 mA DC: 0.1 to 5.5 mA
Lower cutoff current setting range AC: 0.1 to 55 mA DC: 0.1 to 5.5 mA
Judgement Accuracy ±(5% of upper cutoff current + 20μA)
Current Detection Integration of current absolute value followed
by comparison with reference value.
Calibration With rms value of sine wave using a pure
resistance load.
No-load output voltage required
for detection
Approx. 970 V when set to 50 mA AC
Approx. 160 V when set to 5 mA DC
Test Time Setting Range 0.5 to 999 sec (±10 ms) (timer-off function
provided)
Accuracy ±20 ms
Line Voltage 100V±10%, 50/60 Hz (Nominal voltages of
110V, 120V, 220V, 230V and 240V
available as factory options.)
Power Requirements
for line voltage of 100 V Max. 50 VA under no-load conditions
/ Approx. 600 VA at rated load
for line voltage of 100 V to 200 V Max. 50 VA under no-load conditions
/ Approx. 600 VA at rated load
for line voltage of 220 V to 240 V Max. 50 VA under no-load conditions
/ Approx. 610 VA at rated load
Electromagnetic compatibility (EMC) *3 Conforms to the requirements of the
following directive and standard.*2
EMC Directive 2004/108/EC
EN 61326-1
EN 61000-3-2
EN 61000-3-3
Under following conditions
- Used HV test leadwires which is
supplied.
- No discharge in testing.
- Used the shielded cable which length is
less than three meters when the SIGNAL
I/O is used.
Safty Conforms to the requirements of the following
directive and standard.
Low Voltage Directive 2006/95/EC
EN 61010-1 Pollution degree 2
U L1244( T h e U L – a p p r o v e d p r o d u c t s
with input voltage of 120VAC satisfy the
UL1244 standerd.)
Insulation resistance 30 MΩ or more (500 V DC)
Hipot 1390 VAC, 2 seconds [between the AC LINE and chassis]
1200 VAC, 1 second [UL-approved products only]
Environment Specification range : 5 °C to 35°C / 20 %rh to 80 %rh
Operable range : 0 °C to 40°C / 20 %rh to 80 %rh
Storage range : -20 °C to 70 °C / 80 %rh or less
Dimensions (maximum) 430[16.9 inch] W × 177[6.97 inch] (195[7.68 inch]) H × 370[14.6 inch] (450[17.7 inch]) D mm
Weight
Lie voltage of 100 V Approx. 21 kg (Approx. 46.30 lbs)
Line voltage of 100 V to 120 V Approx. 23 kg (Approx. 50.70 lbs)
Line voltage of 220 V to 240 V Approx. 24 kg (Approx. 52.91 lbs)
Accessories
High-voltage test lead TL01-TOS (max.allowablevoltage: 5 kV /1.5m)
TL03-TOS (max.allowablevoltage: 10 kV /1.5m)
Others 14-pin amphenol plug (assembled)